High Voltage Test Lab

The PCORE High Voltage Laboratory
Center for Research and Development of EHV Products
Lapp has a long-term Agreement to access and utilize the HVL with PCORE. PCORE laboratory facilities for high voltage and extra-high voltage testing of insulators and bushings are unsurpassed in the industry. Both indoor and outdoor facilities, designed to operate separately or jointly, provide for impulse, switching surge, 60-cycle, radio noise, corona, load-life, and heat run testing.
 
The indoor facilities of the PCORE High Voltage Laboratory are housed in a grounded, metal-walled building containing an impulse generator rated 2,250,000 volts at 28 kilojoules, a 60-cycle test set consisting of two transformers arranged in cascade with voltages from zero to 1,000,000 volts at 0.2 amperes and high current equipment for testing to 10,000 amperes. The indoor laboratory has facilities for conducting partial discharge tests / radio influence voltage (RIV) tests at a maximum of 600,000 volts to ground for corona measurement.
 
The outdoor, EHV complex has a totally enclosed, all weather surge generator rated at 4,3000,000 volts at 115 kilojoules, controllable as to wave shape for all impulse (1.2 x 50 microseconds) and switching surge (200 x 4,000 microseconds) testing of insulator assemblies and bushings with operating voltages to 765 kV with both resistance and capacitance voltage dividers available. The outdoor testing area also offers a 60-cycle test set consisting of three transformers arranged in cascade with voltages from zero to 1,500,000 volts at 0.2 amperes.

Special facilities for producing water at any desired resistivity at a rate of approximately 125 gallons per minute feed a bank of spray towers which produce a controlled spray for wet tests, capable of handling assemblies as large as switches at 2,050 BIL.

A full scale transmission test tower is available in the outdoor laboratory for design testing of 500 kV suspension/hardware assemblies has a 50-foot window for center phase testing, a 35-foot arm for outside phase assemblies and a 100-foot spans to dead-end towers. Movable structural members mounted within the test tower allow simulation of any transmission tower window design.